Address | 1754 W 1300 N, SALT LAKE CITY, UT 84116 |
Type | Condo/Apartment |
Last Rank | ??? |
First Seen | Wed, 13 Dec 2023 00:14:52 -0700 |
Last Seen | Tue, 1 Jul 2025 22:50:32 -0600 |
Phone Number | (801) 533-0059 |
Code | Observed Violations | Points | Critical | Occurrences | COS | PHR |
---|---|---|---|---|---|---|
4.1.6 (i) | There is no evidence that the certified operator is a registered operator with the Salt Lake County Health Department. | false | 1 | false | RPO - up to 10 pools | |
4.1.6 (vii) | Facility does not have a pool data and specifications summary form in the pump room available for review. | false | 1 | false | RPO - Duties of Registered Pool Operator | |
4.2 | Potable water supply is not protected from cross connections and/or backflow by an air gap or backflow preventer. (faucet does not appear to have backflow installed on it and hose is filling the pool by being suck directly into the water in the pool) | false | 1 | false | Water Supply | |
4.20.8 | Ring buoy does not have rope equal to the maximum width of the pool plus 10 feet. (buoy must be hung out in pool area) Pool lacks shepherd’s crook. | false | 2 | false | Safety Requirements and Lifesaving Equipment - Lifesaving and Safety Equipment |
Code | Observed Violations | Points | Critical | Occurrences | COS | PHR |
---|---|---|---|---|---|---|
4.10.2 | Grab rails are not rigidly installed. | false | 1 | false | Handrails (or grabrails)-rigidly installed | |
4.12.1 | Gates are not self-closing and self latching. Required closure for unsecured gate. | false | 1 | false | Fencing and Barriers |
Code | Observed Violations | Points | Critical | Occurrences | COS | PHR |
---|
Code | Observed Violations | Points | Critical | Occurrences | COS | PHR |
---|---|---|---|---|---|---|
4.12.1 | Gates are not self-closing and self latching. Required closure for unsecured gate. When, I arrived I observed that the gate was left open with a construction cone. | false | 1 | false | Fencing and Barriers |
Code | Observed Violations | Points | Critical | Occurrences | COS | PHR |
---|
Code | Observed Violations | Points | Critical | Occurrences | COS | PHR |
---|---|---|---|---|---|---|
4.24.1 | Free chlorine disinfectant residual less than 1 ppm (required closure) | false | 1 | false | Disinfection and Quality of Water-Disinfection Process | |
4.30 | Disinfectant residuals are not kept in range. Required closure < 0.5 ppm or > 10 ppm. | false | 1 | false | Closing of a Pool | |
5.4 | Operation of the pool in a way that causes or creates a threat to the public health, safety, or the environment. | false | 1 | false | Suspension or Revocation of License or Permit | |
5.5.2 | Second permit suspension within a year (minimum 7-day closure). A third permit suspension within a year may result in permit revocation for a minimum of 30 days for a seasonal pool and minimum 90 days for a year-round pool. | false | 1 | false | Second Permit Suspension Within a Year |
Code | Observed Violations | Points | Critical | Occurrences | COS | PHR |
---|---|---|---|---|---|---|
4.1.6 (vii) | Facility does not have an operation, maintenance, and sanitation plan available for review. Facility has not kept two years of pool data records. Facility does not have a pool data and specifications summary form in the pump room available for review. | false | 1 | false | RPO - Duties of Registered Pool Operator | |
4.10.2 | Grab rails are not rigidly installed. | false | 1 | false | Handrails (or grabrails)-rigidly installed | |
4.14.5 | The flow rate indicator is not working. | false | 1 | false | Rate-Of-Flow Indicator | |
4.17.2 | (v) Skimmer(s) missing weir. (vii) Skimmer(s) missing float valve/check valve assembly. | false | 1 | false | Skimmer System Design | |
4.20.9 | Lifesaving equipment is not maintained in good repair and operable condition. | false | 1 | false | Lifesaving equipment-mounted in readily accessible place |
Code | Observed Violations | Points | Critical | Occurrences | COS | PHR |
---|
Code | Observed Violations | Points | Critical | Occurrences | COS | PHR |
---|---|---|---|---|---|---|
4.30 | Disinfectant residuals are not kept in range. Required closure < 0.5 ppm or > 10 ppm. | false | 1 | false | Closing of a Pool | |
5.4 | Operation of the pool in a way that causes or creates a threat to the public health, safety, or the environment. | false | 1 | false | Suspension or Revocation of License or Permit | |
5.5.1 | First closure. | false | 1 | false | First Permit Suspension |
Code | Observed Violations | Points | Critical | Occurrences | COS | PHR |
---|
Code | Observed Violations | Points | Critical | Occurrences | COS | PHR |
---|