Details for COMFORT INN

Address 440 W 5300 S, MURRAY, UT 84123
Type HOTEL/MOTEL
Last Rank ???
First Seen Wed, 13 Dec 2023 03:12:37 -0700
Last Seen Thu, 22 May 2025 22:46:10 -0600
Phone Number (801) 506-8000

Inspections

Code Observed Violations Points Critical Occurrences COS PHR

Code Observed Violations Points Critical Occurrences COS PHR

Code Observed Violations Points Critical Occurrences COS PHR
4.7.3 Multiple window screen needs repair. false 1 false Exterior Openings Have Operating Locks and are Weather Tight, Rodentproof, In Good Repair. One Entry Door has an Exterior Lock. Open-able Window Screens Properly Installed and Maintained

Code Observed Violations Points Critical Occurrences COS PHR

Code Observed Violations Points Critical Occurrences COS PHR
4.5.6 Hose is not protected from backflow in laundry room. false 1 false Plumbing Systems Properly Constructed, Installed and Maintained
4.7.5 Smoke detector in room 208 is not working and possibly disconnected. false 1 false Smoke Detectors and Fire Extinguishers are Properly Installed and Maintained

Code Observed Violations Points Critical Occurrences COS PHR
4.5.6 Backflow rating on the chemical dispenser does not meet Utah plumbing code. false 1 false Plumbing Systems Properly Constructed, Installed and Maintained
4.7.5 Smoke alarm/actuator #70 and possibly others do not signal (blink red) they are working. false 1 false Smoke Detectors and Fire Extinguishers are Properly Installed and Maintained

Code Observed Violations Points Critical Occurrences COS PHR
4.5.6 Plumbing at mop sink and chemical dispenser do not meet Utah Plumbing Code. Solder on copper pipe joint at water heater is leaking. false 2 false Plumbing Systems Properly Constructed, Installed and Maintained
4.7.3 Some screens are missing on windows that open. false 1 false Exterior Openings Have Operating Locks and are Weather Tight, Rodentproof, In Good Repair. One Entry Door has an Exterior Lock. Open-able Window Screens Properly Installed and Maintained

Code Observed Violations Points Critical Occurrences COS PHR
4.5.4 Electrical plug in laundry room is missing a cover. Also, Electrical panel and junction box in electrical room do not have their covers on them. Electrical panels in electrical room are blocked with equipment, false 4 false Electrical Properly Installed and Maintained
4.6.4 Chemical dispenser does not meet plumbing code. Downstream shutoff valves after atmospheric vacuum breaker does not meet plumbing Code. Piping on water heater is leaking. false 3 false Plumbing Fixtures Maintained Clean and Sanitary
4.7.3 More than 10 windows do not have screens. false 10 false Exterior Openings Have Operating Locks and are Weather Tight, Rodentproof, In Good Repair. One Entry Door has an Exterior Lock. Open-able Window Screens Properly Installed and Maintained
4.7.5 Half of the 6 fire/smoke alarms are not working or not plugged in. false 10 false Smoke Detectors and Fire Extinguishers are Properly Installed and Maintained
4.8.7 (i) Pet policy is not complete. false 1 false Guests not Disturbed by Pet Allergens, Odors, Noise, Nuisances
4.8.8 UICAA Only the front door has a no smoking sign. All entrances are required to be posted. false 5 false Utah Indoor Clean Air Act Compliance

Code Observed Violations Points Critical Occurrences COS PHR
4.5.4 Elictrical box in electrical room does not have a cover on it. false 1 false Electrical Properly Installed and Maintained
4.6.4 Mop sink chemical dispenser does not have correct basckflow rating required. false 1 false Plumbing Fixtures Maintained Clean and Sanitary
4.7.3 20+ windows do not have screens on them allowing mosquitos, bats and stinging insects to enter when the windows are open. false 20 false Exterior Openings Have Operating Locks and are Weather Tight, Rodentproof, In Good Repair. One Entry Door has an Exterior Lock. Open-able Window Screens Properly Installed and Maintained
4.8.2 Dirty pillows are being stored on clean shelves. false 1 false Beds Maintained in a Sanitary Condition. All Bedding Kept Clean, Good Repair. Pillowcases, Sheets Cover Mattress and Pillows Completely. Bedding Replaced with Clean Linen Weekly, and Between Each Occupant
4.8.4 Ice machine has not been cleaned (cleaning solution used) according to manufacturer's instructions. Solution is not available to use on Scotsman machine. false 1 false Automatic Dispensing for Guest Use Ice Machines
4.8.5 Water heater has evidence of a slow leak corroding the water heater. false 1 false All Building, Rooms, Equipment and Grounds in Clean and Safe Condition
4.8.7 (i) The facility does not have the required pet policy in use (as was used by the previous owners). Please see Health regulations for requirements. false 1 false Guests not Disturbed by Pet Allergens, Odors, Noise, Nuisances

Code Observed Violations Points Critical Occurrences COS PHR
4.5.4 Breaker cover in electrical room is not installed. false 1 false Electrical Properly Installed and Maintained
4.6.4 Ecolab chemical dispenser in laundry room does not meet plumbing code. Backflow rating is1055B not 112.1.2. false 1 false Plumbing Fixtures Maintained Clean and Sanitary
4.7.3 There are several windows on the 3d and 2nd floors that do not have screens. The first floor windows are locked with bars and do not have screens. false 1 false Exterior Openings Have Operating Locks and are Weather Tight, Rodentproof, In Good Repair. One Entry Door has an Exterior Lock. Open-able Window Screens Properly Installed and Maintained
4.8.8 UICAA | Exterior entry doors do not have the correct no smoking signs to indicate no smoking within 25 feet of the door. Room 109 and 208 smells strongly of cigarette smoke where someone has obviously been smoking. false 9 false Utah Indoor Clean Air Act Compliance