| Code | 
                                Observed Violations | 
                                Points | 
                                Critical | 
                                Occurrences | 
                                COS | 
                                PHR | 
                            
                            
                                | 4.4.105 | 
                                Single service items are stored in the splash zone of the hand sink in the warewashing room. | 
                                 | 
                                false | 
                                1 | 
                                false | 
                                Equipment, Utensils, Linens, and Single-Service and Single-Use Articles-Storage | 
                            
                            
                                | 4.4.61 | 
                                The mop sink is not sealed to the adjacent wall. | 
                                 | 
                                false | 
                                1 | 
                                false | 
                                Fixed Equipment-Spacing or Sealing | 
                            
                            
                                | 4.4.63 | 
                                The condenser unit in the walk-in freezer is leaking and creating ice build up. The can opener blade is not sharp enough to prevent creation of metal fragments. | 
                                 | 
                                false | 
                                2 | 
                                false | 
                                Good Repair and Proper Adjustment | 
                            
                            
                                | 4.6.1 | 
                                The brace forvthe trenchvdrain at the 3 compartment sink is made of unsealed wood. | 
                                 | 
                                false | 
                                1 | 
                                false | 
                                Surface Characteristics-Indoor Areas | 
                            
                            
                                | 4.6.40 | 
                                The walls are damaged under the 1 compartment sink. The floor is damaged at the entrance to the mop closet. | 
                                 | 
                                false | 
                                2 | 
                                false | 
                                Repairing-Physical Facilities | 
                            
                            
                                | 4.6.5 | 
                                The floor/wall juncture lacks coving along the walk-in cooler wall. | 
                                 | 
                                false | 
                                1 | 
                                false | 
                                Floor and Wall Junctures-Coved and Enclosed or Sealed | 
                            
                            
                                | 4.7.2** | 
                                A chemical spray bottle is not labeled with the common name. | 
                                 | 
                                true | 
                                1 | 
                                false | 
                                Working Containers-Common Name** |